Boiler Water Treatment B90 (30Ltr /Jer)
Treat Boiler to have lower pressure (17.5 kg/cm2 – 250 psi). Cocok untuk boiler bertekanan rendah.
- Send to a friend
- View full size
Treat Boiler to have lower pressure (17.5 kg/cm2 – 250 psi). Cocok untuk boiler bertekanan rendah.
PENGENALAN
AR – B.90 merupakan produk dengan formula yang dirancang khusus untuk memelihara air ketel bertekanan rendah (17,5 Kg/cm2 – 250 psi).
KEGUNAAN
KEUNTUNGAN
PEMAKAIAN
CARA PEMAKAIAN
Tuangkan AR – B.90 kedalam tangki pengisian atau pada isapan pompa pengisian air ketel. Dosis pemakaian adalah 6 liter untuk setiap ton air dalam ketel. Cara pengaturan dosis dapat dilakukan dengan Test Kit AR – TB.90.
PENGONTROLAN DOSIS
Pengontrolan dosis ARI – B.90 dilakukan dengan test alkalinitas “P” dari air ketel kira-kira 100 sampai 300 ppm.
Jika pembacaan hasil test alkalinitas “P” kurang dari 100ppm perlu diberikan tambahan AR – B.90 untuk setiap ton air ketel akan menaikkan pembacaan testing alkalinitas “P” sebesar + 170ppm.
Setelah penambahan AR – B.90 tunggu 1 jam sebelum diadakan test ulang.
Bila test alkalinitas “P” melebihi standar 100 – 300ppm, karena dosis terlalu tinggi atau alkalinitas air pengisian memang tinggi, maka ketel perlu dicerat sampai nilai 100 – 300ppm “P” alkalinitas tercapai lagi. Baru kemudian ditambah dengan air yang lebih baik.
ENGLISH VERSION
INTRODUCTION
AR – B.90 it is a design formula to treat Boiler to have lower pressure (17.5 kg/cm2 – 250 psi)
FUNCTION
To protect corrosion and rust and slag water onto boiler
To eliminate water acid
To resistance with clay and easy to process when deposal
Chemical reaction to water into Boiler to contruct clay water
ADVANTAGE
Multi function characteristic to treat Boiler water, easy to use and control and simple Test Kit
To maintaint steam production capacity
To expand Boiler economic period specific pipes
PROCEDURE
Low pressure Boiler
It is economizer with 200 psi
DIRECTION FOR USE
Please pour AR – B.90 to tank or suction pump of Boiler.
Your dosage 6 Liter per ton water Boiler. To control your dosage, use Test Kit AR – TB.90
HOW TO CONTROL YOUR DOSAGE
To control your dosage with alkaline test “P” from Boiler approximately 100 to 300 ppm. If your test shown less 10ppm, you shall be added our AR – B.90. Additional 6 Liter per ton water Boiler, shown alkaline test is approximately 170 ppm.
After finished, please you wait for one hour before re-test.
If your test allow more 100-300 ppm, as your high dosage as well as water alkaline to fill that also is high, your boiler pressured to 100-300 ppm allow, then added water is better
Salinity Control or Boiler Water Chloride Grade / Draw Off Boiler Water
Salty control or chloride grade to boiler to test with Test Kit of Chloride from AR – B 90.
The result of chloride test will directly be blowdown to water or not boiler. Chloride is not change if chemical reaction into boiler to mineral grade into boiler.
The result of chloride test shown at 200 ppm as normal chloride or salty.
If chloride test shown more 200 ppm that blow down and it should be filled with clean water.
CAUTION
Keep a dry, and keep away friom flammable point, if pour, wash with water immediately, keep away directly contact from your skin and eyes, if any wash with clean water immediately